TM 1-1520-238-23
9-534
9.138.
COAXIAL MASS TERMINATION CONNECTOR (MTC) REPAIR continued
OF DAMAGE OR OVERHEATING OUTSIDE OF SLEEVE
COAX. INSULATION MUST NOT SHOW SIGNS
COAX. INSULATION
OBSCURE INSPECTION
SLEEVE MUST NOT BE DARKENED TO
BETWEEN CABLE INSULATION AND CONTACT BODY
SLEEVE MUST HAVE SHRUNK OVER CONDUCTOR
SLEEVE
CONDUCTOR AND INNER TERMINAL
MUST SEE SOLDER FILLET BETWEEN
MELTED AND FLOWED
SOLDER PREFORM
YOU MUST NOT SEE EITHER RING SHAPED
SOLDER JOINTS
SOLDER PREFORM
SHIELD BRAID
REAR INSPECTION WINDOW
BRAID MUST BE VISIBLE THROUGH
ONE OF TWO INSPECTION WINDOWS
MUST SEE CONDUCTOR THROUGH AT LEAST
INNER CONDUCTOR
0.10 INCH MAXIMUM
REAR OF CONTACT BODY TO CABLE INSULATION
CABLE POSITION
0.10 INCH MAX.
SOLDER FILLET VISIBLE
HEAT SHRINKABLE SLEEVE
INSPECTION WINDOW
SHIELD BRAID
INNER CONDUCTOR
INSPECTION WINDOW
TABLE 1
M04-3067-11
GO TO NEXT PAGE