TM 1-1520-238-23
10-173
10.32.
AFT FUEL CELL ACCESS PANEL AND ACCESS COVER REMOVAL/INSTALLATION continued
e. Attach electrical connectors P943 (5) and
P264 (6) to receptacle J2 (7) and receptacle J1
(8).
f. Install hose (12) on union (13). Torque nut (15)
to 120 INCH-POUNDS.
(1) Hold retaining nut (14). Install nut (15).
Torque nut (15) to 120 INCH-POUNDS. Use
torque wrench and crowfoot.
g. Install hose (9) on valve (10). Torque hose nut
(11) to 120 INCH-POUNDS. Use torque wrench
and crowfoot.
(1) Install hose nut (11). Torque hose nut (11) to
120 INCH-POUNDS. Use torque wrench and
crowfoot.
h. Inspect (QA).
i. Install aft fuel cell upper vent tube (para 10.30.
j. Refuel aft fuel cell (para 1.19).
k. Perform fuel quantity indication/transfer
maintenance
operational
check
(TM 1-1520-238-T).
l. Remove aft fuel cell upper vent tube (para
10.30).
GO TO NEXT PAGE
7
8
5
6
M04-0354-9
M04-0354-11
12
15
14
13
10
9
11