TM 1-1520-238-23
Change 2
11-85
11.12.
AFT LONGITUDINAL BELLCRANK REMOVAL/INSTALLATION continued
11.12.3. Removal
WARNING
To prevent bellcrank movement and
possible injury, support bellcrank be-
fore disconnecting servocylinder. If
injury occurs, seek medical aid.
CAUTION
To prevent damage to rigid hydraulic
tubes, ensure upper end of servocylinder
is supported when rod end is discon-
nected from bellcrank.
a. Remove servocylinder (1) from bellcrank (2).
(1) Remove sealant from attaching hardware
(para 1.47).
(2) Remove and discard cotter pin (3).
(3) Hold bolt (4). Remove nut (5). Use open end
wrench and socket.
NOTE
Do not remove nylon washer unless it is
loose or excessively worn.
(4) Remove bolt (4), washer(s) (6), bushing (7),
and nylon washer (8) (if necessary).
b. Remove right side of bellcrank (9) from bell-
crank (2).
(1) Remove sealant from attaching hardware
(para 1.47).
(2) Remove and discard cotter pin (10).
(3) Hold bolt (11). Remove nut (12) and washer
(13). Use socket and open end wrench.
GO TO NEXT PAGE
M04-1719-1
M04-1719-2
3
1
8
4
6
7
2
5
M04-1719-3
2
9
11
13
12
10