TM 1-1520-238-23
11-148
11.27.
COLLECTIVE STICK SEARCHLIGHT ON/OFF SWITCH REPLACEMENT continued
11.27.5. Inspection
a. Check for cracked and broken wires. None al-
lowed.
b. Check removed and attaching parts for
cracks. None allowed.
c. Check removed and attaching parts for dam-
age (para 11.5).
d. Check removed and attaching parts for corro-
sion (para 1.49).
11.27.6. Installation
a. Install new switch (10) on plate (8).
(1) Adjust nut (15) on switch (10) ensuring that
only two threads extend below nut (15).
(2) Install switch (10) on plate (8).
(3) Install keywasher (14), washer (13), and nut
(12) on switch (10).
WARNING
Soldering iron can cause severe
burns to personnel and start fires.
Observe all safety precautions when
using soldering iron. If injury occurs,
seek medical aid.
b. Solder wires (11) to switch (10).
(1) Solder identified wires (11) to switch (10).
Use solder (item 189, App F) and soldering
iron (TM 55-1500-323-24).
GO TO NEXT PAGE
M04-3512-4
12
13
10
8
11
14
15
M04-3512-5
10
11
VIEW ROTATED