11.28.
COLLECTIVE STICK SEARCHLIGHT DIRECTIONAL SWITCH REPLACEMENT continued
c. Remove switch mounting plate (8) from
grip (6).
(1) Remove three screws (9).
(2) Remove plate (8).
d. Remove adhesive from switch (10) terminals
(para 1.47).
WARNING
Soldering iron can cause severe
burns to personnel and start fires.
Observe all safety precautions when
using soldering iron. If injury occurs,
seek medical aid.
e. Desolder wires (11) from switch (10).
(1) Identify and desolder wires (11). Use
soldering iron (TM 55-1500-323-24).
f. Remove switch (10) from plate (8).
(1) Loosen setscrew (12).
(2) Remove and discard switch (10).
11.28.4. Cleaning
a. Clean removed and attaching parts (para
1.47).
GO TO NEXT PAGE
M04-3513-2
10
11
8
9
6
M04-3513-3
10
8
10
11
12
VIEW ROTATED