TM 1-1520-238-23
11-877
11.200.
CPG LONGITUDINAL CONTROL POSITION LINEAR VARIABLE DIFFERENTIAL TRANSDUCER
(LVDT) REMOVAL continued
h. Remove LVDT (14) from bracket (19).
(1) Remove and discard cotter pin (20).
(2) Remove nut (21).
(3) Remove bolt (22) and washer (23).
i. Remove LVDT (14) from rod end (24).
(1) Remove lockwire.
(2) Loosen nut (25).
(3) Remove LVDT (14) from rod end (24).
(4) Remove keywasher (26).
11.200.4. Cleaning
a. Wipe removed and attaching parts with a
clean rag.
11.200.5. Inspection
a. Check removed and attaching parts for dam-
age (para 11.190).
b. Check removed and attaching parts for corro-
sion (para 1.49).
c. Check all removed bushing(s) and/or bear-
ing(s) for wear (para 11.4).
END OF TASK
M04-1855-4
14
26
25
19
21
20
22
23
24