TM 1-1520-238-23
11-874
11.199.
CPG LATERAL CONTROL POSITION LINEAR VARIABLE DIFFERENTIAL TRANSDUCER (LVDT)
INSTALLATION continued
i. Install clamp (28) on harness (9).
(1) Install screw (29) through washer (30), clamp
(28), and spacer (31).
j. Install lead (5) on ground stud (32).
(1) Position lead (5) on stud (32).
(2) Install washer (33) and nut (34).
k. Adjust LVDT null (para 11.216).
l. Remove CPG cyclic stick -5 rig pin (para
11.289).
m. Inspect (QA).
n. Perform lateral flight control rigging mainte-
nance operational check (TM 1-1520-238-T).
o. Install access doors B60 and B65L (para 2.2).
p. Inspect (QA).
END OF TASK
28
30
29
31
9
M04-1854-6
M04-1854-10
34
33
32
5