TM 1-1520-238-23
11-875
11.200.
CPG LONGITUDINAL CONTROL POSITION LINEAR VARIABLE DIFFERENTIAL TRANSDUCER
(LVDT) REMOVAL
11.200.1. Description
This task covers:
Removal. Cleaning. Inspection.
11.200.2. Initial Setup
Tools:
Aircraft mechanics tool kit (item 376, App H)
Personnel Required:
67R
Attack Helicopter Repairer
References:
TM 55-1500-323-24
Equipment Conditions:
Ref
Condition
1.57
Helicopter safed
2.2
Access door B75R removed
11.200.3. Removal
a. Enter pilot station (para 1.56). Observe all
safety precautions.
b. On pilot center circuit breaker panel, open
ASE AC, DC, and BUCS circuit breakers.
GO TO NEXT PAGE
M04-1855-1