TM 1-1520-238-23
Change 8
16-51
16.9.
PYLON ACTUATOR AND TOP PLATE REMOVAL/INSTALLATION - continued
16.9.3. Removal
a. Detach connector P507 (1) from receptacle
J507 (2).
b. Remove pylon actuator rod end (3) from yoke
(4).
(1) Remove and discard cotter pin (5) from bolt
(6).
(2) Hold bolt (6). Remove nut (7) and washer (8).
(3) Remove bolt (6) from yoke (4) and rod end
(3).
(4) Remove rod end (3) from yoke (4).
c. Remove connector plate (9) from top plate
(10).
(1) Remove two screws (11) and washers (12).
WARNING
Maintain pressure on preloaded
spring while removing retaining ring.
A spring-loaded mechanism can
cause injury to personnel if released
in an uncontrolled manner. Always
take care while working with the
mechanism.
(2) Remove two connectors P505 (22) and P508
(23) from plate (9).
(3) Maintain pressure on springs (21). Use wire
(item 225, App F).
(4) Remove retaining ring (19), backing washer
(20), spring (21), and retainer (24).
(5) Remove plate (9) from alinement pins (13).
GO TO NEXT PAGE
1
2
M04-2708-2
M04-2708-3
4
6
3
8
5
7
M04-2708-4A
24
11
12
19
22
20
21
13
10
9
23