TM 11520238T1
458
Change 4
48
MUX SYSTEM INTERACTIVE FD/LS
48
CHECK (cont)
FD/LS NOGO
DISPLAY
CORRECTIVE ACTION
TYPE I MRTU LT
BUS NOGO LH FAB
(ACZ)
Troubleshoot wiring to isolate
fault (TM 9-1230-476-20-2).
TYPE I MRTU NOGO
RH FAB
Troubleshoot wiring to isolate
fault (TM 9-1230-476-20-2). If
troubleshooting does not
remove NOGO, replace
Type I MRTU
(TM 9-1230-476-20-1). If
replacement does not
remove NOGO, replace
FCC (TM 9-1230-476-20-1).
If both Type I MRTU
NOGOs (LH and RH FAB)
appear on HOD, refer to
TM 9-1230-476-20-2.
TYPE I MRTU RT
BUS NOGO RH FAB
(ACZ)
Troubleshoot wiring to isolate
fault (TM 9-1230-476-20-2).
TYPE I MRTU LT
BUS NOGO RH FAB
(ACZ)
Troubleshoot wiring to isolate
fault (TM 9-1230-476-20-2).
DASE MRTU NOGO
AFT AVIONICS BAY
Troubleshoot wiring to isolate
fault (TM 9-1230-476-20-2). If
troubleshooting does not
remove NOGO, replace
DASE computer
(TM 1-1520-238-23). If
replacement does not
remove NOGO, replace
FCC (TM 9-1230-476-20-1).
If NOGO still exists, refer to
TM 9-1230-476-20-2.
DASE MRTU RT
BUS NOGO AFT
AVIONICS BAY (ACZ)
Troubleshoot wiring to isolate
fault (TM 9-1230-476-20-2).
DASE MRTU LT BUS
NOGO AFT
AVIONICS BAY (ACZ)
Troubleshoot wiring to isolate
fault (TM 9-1230-476-20-2).