TM 11520238T1
Change 4
458.1
48
MUX SYSTEM INTERACTIVE FD/LS
48
CHECK (cont)
FD/LS NOGO
DISPLAY
CORRECTIVE ACTION
TYPE II MRTU NOGO
LT OUTBD
Troubleshoot wiring to isolate
fault (TM 9-1230-476-20-2). If
troubleshooting does not
remove NOGO, replace
Type II MRTU on left
outboard pylon
(TM 9-1230-476-20-1). If
replacement does not
remove NOGO, replace
FCC (TM 9-1230-476-20-1).
If NOGO still exists, refer to
TM 9-1230-476-20-2.
TYPE II MRTU RT
BUS NOGO LT
OUTBD (ACZ)
Troubleshoot wiring to isolate
fault (TM 9-1230-476-20-2).
TYPE II MRTU LT
BUS NOGO LT
OUTBD (ACZ)
Troubleshoot wiring to isolate
fault (TM 9-1230-476-20-2).
TYPE II MRTU NOGO
LT INBD
Troubleshoot wiring to isolate
fault (TM 9-1230-476-20-2). If
troubleshooting does not
remove NOGO, replace
Type II MRTU on left inboard
pylon (TM 9-1230-476-20-1).
If replacement does not
remove NOGO, replace
FCC (TM 9-1230-476-20-1).
If NOGO still exists, refer to
TM 9-1230-476-20-2.
TYPE II MRTU RT
BUS NOGO LT INBD
(ACZ)
Troubleshoot wiring to isolate
fault (TM 9-1230-476-20-2).
TYPE II MRTU LT
BUS NOGO LT INBD
(ACZ)
Troubleshoot wiring to isolate
fault (TM 9-1230-476-20-2).