TM 1-1520-238-T-7
11283
1157.
DASE COMPUTER NO-GO AFT AVIONICS BAY APPEARS ON HOD
1157
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 11-1520-238-23-2
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provisions
R295 door open
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Check for 28 VDC at:
P68273,
P68275,
P68277,
P68279.
Is voltage present?
YES
Go to step 4.
NO
Go to step 2.
2. Check for open between all combinations of the
following:
P68273,
P68275,
P68277,
P68279,
P682121.
Does open exist?
YES
Repair open wire between:
P682 SP5 and P68273,
P682 SP5 and P68275,
P682 SP5 and P68277,
P682 SP5 and P68279.
Go to paragraph 1123.
NO
(ACA) Replace DASEC
(TM 1-1520-238-23).
(ACB) Go to step 3.
3. (ACB) Detach filter adapter A705. Check for
open through pins:
A70573,
A70575,
A70577,
A70579,
A705121.
Does open exist?
YES
Replace filter adapter
(TM 1-1520-238-23).
NO
Replace DASEC
(TM 1-1520-238-23).
4. Detach P750. Check for short between:
P68883 and ground,
P68882 and ground.
Does short exist?
YES
Repair shorted wire between:
P68883 and P459A15,
P68882 and P459A16,
J459A15 and J912B18,
J459A16 and J912B19,
P912B18 and P750L,
P912B19 and P750M.
Go to paragraph 1123.
NO
Go to step 5.