TM 1-1520-238-T-7
11285
1158. CPG COLL LVDT NO-GO CPG COMPARTMENT APPEARS ON HOD
1158
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provisions
R295 door open
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Place CPG collective stick to full up or full down.
Detach P686. Check for 10 VAC at P68639.
Is voltage present?
YES
(ACA) Replace DASEC
(TM 1-1520-238-23).
(ACB) Go to step 2.
NO
(ACA) Go to step 3.
(ACB) Go to step 4.
2. (ACB) Attach P686. Detach filter adapter A707.
Check for 10 VAC at A70739.
Is voltage present?
YES
Replace DASEC
(TM 1-1520-238-23).
NO
Replace filter adapter
(TM 1-1520-238-23).
3. (ACA) Check for short between:
P234C and ground,
P234D and ground.
Does short exist?
YES
Repair shorted wire between:
P234D and J447B17,
P234C and J447B18,
P447B17 and P68638,
P447B18 and P68639.
Go to paragraph 1123.
NO
Go to step 5.
4. (ACB) Check for short between:
J2343 and ground,
J2344 and ground.
Does short exist?
YES
Repair shorted wire between:
J2344 and J447B17,
J2343 and J447B18,
P447B17 and P68638,
P447B18 and P68639.
Go to paragraph 1123.
NO
Go to step 6.
5. (ACA) Check for open between:
P234C and P68639,
P234D and P68638.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
Go to step 7.
6. (ACB) Check for open between:
J2343 and P68639,
J2344 and P68638.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
Go to step 9 .
7. (ACA) Attach P686. Check for 26 VAC at
P234A.
Is voltage present?
YES
Go to step 8.
NO
Go to step 11.