1158. CPG COLL LVDT NO-GO CPG COMPARTMENT APPEARS ON HOD (cont)
1158
8. (ACA) Check for open between P234B and
P499B17.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
Replace CPG collective
(vertical) LVDT
(TM 1-1520-238-23).
9. (ACB) Attach P686. Check for 26 VAC at
J2341.
Is voltage present?
YES
Go to step 10.
NO
Go to step 12.
10. Check for open between J2342 and P6934.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
Replace CPG collective
(vertical) LVDT
(TM 1-1520-238-23).
11. (ACA) Check for open between P234A and
P499B16.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
Go to paragraph 1176.
12. (ACB) Check for open between 2341 and
P6933.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
Go to paragraph 1176.
END OF TASK