TM 1-1520-238-T-7
11307
1175.
BUCS TRACER NO-GO APPEARS ON HOD
1175
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provisions
R295 door open
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Check for 28 VDC at P68660.
Is voltage present?
YES
Go to step 2.
NO
Repair open wire between J415
SP1 and P68660.
Go to paragraph 1123.
2. Check for 28 VDC at P68659.
Is voltage present?
YES
Go to step 3.
NO
Repair open wire between J415
SP1 and J417 SP1,
J417 SP1 and J408 SP1,
J408 SP1 and P68659.
Go to paragraph 1123.
3. Check for 28 VDC at P68661.
Is voltage present?
YES
Go to step 5.
NO
Go to step 4.
4. Check for 28 VDC at J75624.
Is voltage present?
YES
Repair open wire between:
P75624 and J215 SP1,
J215 SP1 and J75622,
J75622 and P402B17,
J402B17 and P68661.
Go to paragraph 1123.
NO
Repair open wire between:
J75624 and P402B19.
(A323):
J5A4 and TB34P.
(ACA) J402B19 and P499A4.
(ACB) J402B19 and
P693 SP1,
P693 SP1 and P499A4.
Go to paragraph 1123.
5. Check for 28 VDC at P68662.
Is voltage present?
YES
Go to step 6.
NO
Repair open wire between:
J417 SP1 and P449A3,
P499A7 and P68662.
(A323):
J5A3 and TB33J,
TB33K and J5A7.
Go to paragraph 1123.
6. Check for 28 VDC at P68651.
Is voltage present?
YES
Go to step 10.
NO
Go to step 7.
7. Check for 28 VDC at J2661.
Is voltage present?
YES
Go to step 8.
NO
Go to step 9.