TM 1-1520-238-T-7
11304
Change 3
1172. CPG LAT 1 DCPLR NO-GO CPG COMPARTMENT OR CPG LAT 2 DCPLR
1172
NO-GO CPG COMPARTMENT APPEARS ON HOD
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provisions
R295 door open
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. With BUCS TST switch held in PLT or CPG
position, check for 28 VDC at P686123 and
P686124.
Is voltage present?
YES
Go to step 2.
NO
Go to step 4.
2. Check CPG lateral SPAD shear pin condition
(TM 1-1520-238-23).
Is shear pin sheared?
YES
Replace SPAD shear pin
(TM 1-1520-238-23).
NO
Go to step 3.
3. Detach P413 and P459. Check for short
between:
J2661 and J2662,
J2661 and J2664.
Does short exist?
YES
Repair shorted wire between:
J2661 and P413B5,
J2662 and J459A18,
J2664 and J459A5.
Go to paragraph 1123.
NO
Replace CPG cyclic housing
(TM 1-1520-238-23).
4. Check for open between:
J2662 and P686123,
J2664 and P686124.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
Go to step 5.
5. Check for open between:
P12 and P13,
P13 and P14.
Does open exist?
YES
Replace CPG cyclic housing
(TM 1-1520-238-23).
NO
(ACA) Replace DASEC
(TM 1-1520-238-23).
(ACB) Go to step 6.
6. (ACB) Detach filter adapter A708. Check for
open through pins A707123 and A707124.
Does open exist?
YES
Replace filter adapter
(TM 1-1520-238-23).
NO
Replace DASEC
(TM 1-1520-238-23).
END OF TASK