TM 1-1520-238-T-7
Change 3
11303
1171. CPG LONG 1 DCPLR NO-GO CPG COMPARTMENT OR CPG LONG 2 DCPLR
1171
NO-GO CPG COMPARTMENT APPEARS ON HOD
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provisions
R295 door open
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. With BUCS TST switch held in PLT or CPG
position, check for 28 VDC at P686115 and
P686122.
Is voltage present?
YES
Go to step 2.
NO
Go to step 4.
2. Check CPG longitudinal SPAD shear pin
condition (TM 1-1520-238-23).
Is shear pin sheared?
YES
Replace SPAD shear pin
(TM 1-1520-238-23).
NO
Go to step 3.
3. Detach P472 and P459. Check for short
between:
J2711 and J2712,
J2711 and J2714.
Does short exist?
YES
Repair shorted wire between:
J2671 and P472A18,
J2672 and P908A1,
J2674 and P908A7,
J908A1 and J459A19,
J908A7 and J459A3.
Go to paragraph 1123.
NO
Replace CPG cyclic housing
(TM 1-1520-238-23).
4. Check for open between:
J2672 and P686115,
J2674 and P686122.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
Go to step 5.
5. Check for open between:
P12 and P13,
P13 and P14.
Does open exist?
YES
Replace CPG cyclic housing
(TM 1-1520-238-23).
NO
(ACA) Replace DASEC
(TM 1-1520-238-23).
(ACB) Go to step 6.
6. (ACB) Detach filter adapter A707. Check for
open through pins A707115 and A707122.
Does open exist?
YES
Replace filter adapter
(TM 1-1520-238-23).
NO
Replace DASEC
(TM 1-1520-238-23).
END OF TASK