TM 1-1520-238-T-7
Change 3
11305
1173. CPG DIR 1 DCPLR NO-GO CPG COMPARTMENT OR CPG DIR 2 DCPLR
1173
NO-GO CPG COMPARTMENT APPEARS ON HOD
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provisions
R295 door open
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. With BUCS TST switch held in PLT or CPG
position, check for 28 VDC at P686125 and
P686126.
Is voltage present?
YES
Go to step 2.
NO
Go to step 4.
2. Check CPG directional SPAD shear pin
condition (TM 1-1520-238-23).
Is shear pin sheared?
YES
Replace shear pin
(TM 1-1520-238-23).
NO
Go to step 3.
3. Detach P472 and P459. Check for short
between:
J2731 and J2732,
J2731 and J2734.
Does short exist?
YES
Repair shorted wire between:
J2731 and P472A17,
J2732 and P908A2,
J2734 and P908A4,
J908A2 and J459A20,
J908A4 and J459A4.
Go to paragraph 1123.
NO
Replace directional SPAD
(TM 1-1520-238-23).
4. Check for open between:
J2732 and P686125,
J2734 and P686126.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
Go to step 5.
5. Check for open between:
P12 and P13,
P13 and P14.
Does open exist?
YES
Replace directional SPAD
(TM 1-1520-238-23).
NO
(ACA) Replace DASEC
(TM 1-1520-238-23).
(ACB) Go to step 6.
6. (ACB) Detach filter adapter A707. Check for
open through pins A707125 and A707126.
Does open exist?
YES
Replace filter adapter
(TM 1-1520-238-23).
NO
Replace DASEC
(TM 1-1520-238-23).
END OF TASK