TM 1-1520-238-T-7
11302
Change 3
1170. PILOT COLL 1 DCPLR NO-GO PLT COMPARTMENT OR PILOT COLL 2 DCPLR
1170
NO-GO PLT COMPARTMENT - APPEARS ON HOD
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provisions
R295 door open
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. With BUCS TST switch held in PLT or CPG
position, check for 28 VDC at P688127 and
P688128.
Is voltage present?
YES
Go to step 2.
NO
Go to step 4.
2. Check pilot collective SPAD shear pin condition
(TM 1-1520-238-23).
Is shear pin sheared?
YES
Replace SPAD shear pin
(TM 1-1520-238-23).
NO
Go to step 3.
3. Detach P413 and P459. Check for short
between:
J2721 and J2722,
J2721 and J2724.
Does short exist?
YES
Repair shorted wire between:
J2721 and P413B15,
J2722 and J459A9,
J2724 and J459A13.
Go to paragraph 1123.
NO
Replace pilot collective housing
(TM 1-1520-238-23).
4. Check for open between:
J2722 and P688127,
J2724 and P688128.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
Go to step 5.
5. Check for open between:
P12 and P13,
P13 and P14.
Does open exist?
YES
Replace pilot collective housing
(TM 1-1520-238-23).
NO
(ACA) Replace DASEC
(TM 1-1520-238-23).
(ACB) Go to step 6.
6. (ACB) Detach filter adapter A708. Check for
open through pins A708127 and A708128.
Does open exist?
YES
Replace filter adapter
(TM 1-1520-238-23).
NO
Replace DASEC
(TM 1-1520-238-23).
END OF TASK