1174. CPG COLL 1 DCPLR NO-GO CPG COMPARTMENT OR CPG COLL 2 DCPLR
1174
NO-GO CPG COMPARTMENT APPEARS ON HOD
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provisions
R295 door open
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. With BUCS TST switch held in PLT or CPG
position, check for 28 VDC at P686127 and
P686128.
Is voltage present?
YES
Go to step 2.
NO
Go to step 4.
2. Check CPG collective SPAD shear pin condition
(TM 1-1520-238-23).
Is shear pin sheared?
YES
Replace SPAD shear pin
(TM 1-1520-238-23).
NO
Go to step 3.
3. Detach P413 and P459. Check for short
between:
J2681 and J2682,
J2681 and J2684.
Does short exist?
YES
Repair shorted wire between:
J2681 and P413B12,
J2682 and J459A6,
J2684 and J459A2.
Go to paragraph 1123.
NO
Replace CPG collective support
housing
(TM 1-1520-238-23).
4. Check for open between:
J2682 and P686127,
J2684 and P686128.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
Go to step 5.
5. Check for open between:
P12 and P13,
P13 and P14.
Does open exist?
YES
Replace CPG collective support
housing
(TM 1-1520-238-23).
NO
(ACA) Replace DASEC
(TM 1-1520-238-23).
(ACB) Go to step 6.
6. (ACB) Detach filter adapter A707. Check for
open through pins A707127 and A707128.
Does open exist?
YES
Replace filter adapter
(TM 1-1520-238-23).
NO
Replace DASEC
(TM 1-1520-238-23).