TM 1-1520-238-T-7
11333
1184. PILOT DIR LVDT NO-GO PLT COMPARTMENT APPEARS ON HOD
1184
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
References:
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provisions
R295 door open
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Place pilot directional pedals to full right or full
left. Check for 10 VAC at P68818.
Is voltage present?
YES
(ACA) Replace DASEC
(TM 1-1520-238-23).
(ACB) Go to step 2.
NO
(ACA) Go to step 3.
(ACB) Go to step 4.
2. (ACB) Attach P688. Detach filter adapter A708.
Check for 10 VAC at A70815.
Is voltage present?
YES
Replace filter adapter
(TM 1-1520-238-23).
NO
Replace DASEC
(TM 1-1520-238-23).
3. (ACA) Detach P688. Check for short between:
P231C and ground,
P231D and ground.
Does short exist?
YES
Repair shorted wire between:
P231D and P912B5,
P231C and P912B6,
J912B5 and J459B12,
J912B6 and J459B13,
P45912 and P68817,
P45913 and P68818.
Go to paragraph 1123.
NO
Go to step 5.
4. (ACB) Detach P688. Check for short between:
J2313 and ground,
J2314 and ground.
Does short exist?
YES
Repair shorted wire between:
J2314 and P912B5,
J2313 and P912B6,
J912B5 and J459B12,
J912B6 and J459B13.
P45912 and P68817,
and P45913 and P68818.
Go to paragraph 1123.
NO
Go to step 6.
5. (ACA) Check for open between:
P231C and P68818,
P231D and P68817.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
Go to step 7.
6. (ACB) Check for open between:
J2313 and P68818,
J2314 and P68817.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
Go to step 9.