TM 1-1520-238-23
8-63
8.23.
PILOT/CPG ENGINE INSTRUMENT DIM/TEST CONTROL PANEL DISASSEMBLY/ASSEMBLY
(AVIM) continued
b. Clean desoldered contacts and terminals. Use
alcohol (item 25, App F) and brush (item 34,
App F) (TM 55-1500-323-24).
8.23.5. Inspection
a. Check wires for wear, cuts, breaks, and dam-
aged connections (TM 55-1500-323-24).
b. Check connector for bent or damaged pins
(TM 55-1500-323-24).
8.23.6. Assembly
WARNING
Soldering iron can cause severe
burns to personnel and start fires.
Observe all safety precautions when
using soldering iron. If injury occurs,
seek medical aid.
a. Install connector (17) in case (2).
(1) Position connector (17) in case (2).
(2) Install screwlock (19) through case (2) and
connector (17).
(3) Hold screwlock (19).
(4) Install nut (20) on screwlock (19).
(5) Attach 10 identified wires (18) to connector
(17). Use soldering iron and solder (item 189,
App F) (TM 55-1500-323-24).
GO TO NEXT PAGE
M04-3544-7
2
19
17
20
18