TM 1-1520-238-23
8-102
Change 4
8.39.
PITOT STATIC SYSTEM TUBING SPLICE REPLACEMENT continued
8.39.3. Removal
WARNING
Do not place heater near flammable
material or allow heater to contact
skin: severe burns can result. Wear
protective equipment. If injury occurs,
seek medical aid.
a. Remove splice (1) from convoluted tubing (2)
and smooth tubing (3).
(1) Heat splice (1). Use protective gloves and
heater.
(2) While splice (1) is hot, hold tubing (2) and
tubing (3).
(3) Remove splice (1) from tubing (2) and tubing
(3).
8.39.4. Cleaning
a. Clean all parts to be covered with sleeving.
Use methyl ethyl ketone (item 124, App F) and
cloth (item 52, App F).
8.39.5. Inspection
a. Tubing and sleeving shall be free from holes,
cracks, or nicks. Ends shall be cut smooth and
shall be free of ragged edges.
GO TO NEXT PAGE
M04-3732-1
2
1
3
M09-3732-5
2
1
3