TM 1-1520-238-23
8-103
8.39.
PITOT STATIC SYSTEM TUBING SPLICE REPLACEMENT continued
8.39.6. Installation
WARNING
Do not place heater near flammable
material or allow heater to contact
skin: severe burns can result. Wear
protective equipment. If injury occurs,
seek medical aid.
NOTE
If installing splice over convoluted tub-
ing and adapter, go to step a.
If installing splice over pitot tubing and
convoluted tubing, go to step b.
If installing splice over static tubing
and convoluted tubing, go to step c.
If installing splice in middle of tubing to
cover crack or break, go to step d.
a. Install splice (1) over convoluted tubing (2)
and adapter (4).
(1) Cut one 1.0 INCH splice from sleeving instal-
lation. Use insulation sleeving (item 104,
App F).
(2) Apply adhesive to splice area. Fill in all val-
leys on convoluted tubing (2). Use adhesive
(item 9, App F).
(3) Slide splice (1) over tubing (2).
GO TO NEXT PAGE
M04-3732-2
1
4
2
1.00
0.42