TM 1-1520-238-23
9-510
9.135.
MASS TERMINATION CONNECTOR (MTC) (1 OR 2 INCH) REPAIR continued
WARNING
Do not place heater near flammable
material or allow heater to contact
skin: severe burns can result. Wear
protective equipment. If injury occurs,
seek medical aid.
i. Remove wire (10) from wafer (6). Use heating
tool kit, nitrogen (item 128, App F) (if on helicop-
ter), foil shield, and tweezers.
(1) Heat sleeve (11) until solder (16) melts.
(2) While solder (16) is melting, pull wire (10) free
of sleeve (11) with tweezers.
(3) Remove sleeve (11) and excess solder (16)
from wafer terminal (17).
(4) Repeat steps i.(1) thru i.(3) for all wires (10)
marked for removal.
j. Repeat steps d. thru i. for wafer (7).
9.135.4. Cleaning
a. Wipe connector and wires with a clean rag.
9.135.5. Inspection
a. Check removed and attaching parts for dam-
age (para 9.126).
b. Check wires and terminals for wear, cracks,
cuts, broken strands and proper strip
sizes.(para 9.126).
c. Check removed and attaching parts for corro-
sion (para 1.49).
d. Check wires are free of residue and excess
solder.
GO TO NEXT PAGE
10
11
6
11
M04-3065-27
M04-3065-28
11
16
17
10
M04-3065-10
STRIP DIMENSION
.150 ± .020 IN