TM 1-1520-238-23
10-461
10.111.
APU FUEL SHUTOFF VALVE REMOVAL/INSTALLATION continued
c. Detach connector P52 (1) from receptacle
(L20)J1 (2) on APU fuel shutoff valve (3).
d. Unlatch and remove retainer (4) from valve (3).
e. Slide body (5) on fuel fitting (6) until body is
free of valve (3).
f. Remove APU fuel inlet tube (7) from valve (3).
(1) Hold elbow (8). Remove tube nut (9).
g. Remove valve (3) from bracket (13).
(1) Hold two bolts (10). Remove two nuts (12)
and washers (11).
(2) Remove two bolts (10) and washers (11).
h. Remove and discard packing (14) from valve
(3).
i. Remove body (5) from fitting (6).
j. Remove and discard packing (15).
GO TO NEXT PAGE
3
1
2
4
M04-412-2
4
6
5
M04-412-3
7
3
9
8
11
12
13
14
3
10
11
M04-412-4
6
15
5
M04-412-5