TM 1-1520-238-23
11-140
11.24.
COLLECTIVE STICK GRIP ASSEMBLY REMOVAL/INSTALLATION continued
b. Pin wire bundles (3) and (4) to connector (1).
(1) Remove lockwire (12) (if used).
(2) Slide backshell (5) over wire bundles (3) and
(4).
(3) Pin identified wires (7) from wire bundles (3)
and
(4)
to
connector
(1)
(TM 55-1500-323-24).
(4) Install backshell (5) on connector (1).
(5) Install new tape (6) on wire bundles (3) and
(4) (as required). Use tape (item 202, App F).
c. Perform continuity test. Use multimeter
(TM 55-1500-323-24).
d. Attach connector P107 (pilot)/P108 (CPG) (1)
to receptacle J107 (pilot)/J108 (CPG) (2).
e. Inspect (QA).
END OF TASK