TM 1-1520-238-23
11-1267
11.295.
RIGGING PILOT AND CPG DIRECTIONAL PEDAL STOP BOLTS continued
m. Measure and record distance between valve
arm (9) and stop bolt (10) on servocylinder (7).
(1) This is measurement B. Use caliper.
(2) If difference between measurement A and B
is more than 0.030 INCH, move pilot left ped-
al (2) forward until difference between mea-
surement A and measurement B is less than
0.030 INCH.
(3) If difference between measurements A and B
is less than 0.030 INCH go to next step.
(4) Hold pedals (2) and (3) in this position.
n. Adjust bolt (12) to contact SPAD (1).
(1) Rotate bolt (12) counterclockwise to contact
SPAD (1).
(2) Hold bolt (12). Tighten nut (13).
(3) Lockwire stop bolt (12) to nut (13), and brack-
et (14). Use wire (item 224, App F).
o. Adjust bolt (16) for a 0.020 INCH gap between
bolt (16) and CPG SPAD (20).
(1) Hold pedal (3) forward to maintain contact
between SPAD (1) and bolt (12).
(2) Hold 0.020 INCH thickness gage (21) against
CPG SPAD (20).
(3) Rotate bolt (16) counterclockwise until it con-
tacts gage (21) held against SPAD (20).
(4) Hold bolt (16). Tighten nut (17).
(5) Lockwire stop bolt (16) to nut (17) and brack-
et (18). Use wire (item 224, App F).
GO TO NEXT PAGE
M04-3028-8
B
10
9
7
PILOT STATION
M04-3028-12
2
3
12
M04-3028-9
1
13
14
M04-3028-10
17
18
21
20
16
18