PYLON RACK EJECTOR IMPULSE CARTRIDGE REMOVAL/INSTALLATION - continued
d. Verify that safety pin (1) is installed in pylon
rack (2).
WARNING
Static electricity can accidentally fire
ejection cartridge. To prevent possible
injury to personnel or cause damage
to equipment, do not touch cartridge
primer. If injury occurs, seek medical
aid.
e. Remove housing (3) from rack (2).
(1) Remove lockwire from housing (3).
(2) Unscrew housing (3) from rack (2).
f. Remove cartridge (4) from housing (3). Do not
touch primer (5).
(1) Remove cartridge (4) out of housing (3). Do
not touch primer (5).
(2) Place cartridge (4) in storage container (6)
(TM 9-1300-206).
16.3.4. Cleaning
NOTE
Anytime stores are jettisoned, clean and
inspect jettison rack (para 16.7).
a. Wipe impulse cartridge mounting area with a
clean rag.
16.3.5. Inspection
a. Check cartridge mounting area for cracks
(para 16.1).
b. Check cartridge mounting area for corrosion
(para 1.49).