TM 1-1520-238-23
16-18
Change 8
16.4.
PYLON RACK REMOVAL/INSTALLATION - continued
e. Remove wire harnesses (19) and (20) from
support clamp (21).
(1) Remove screw (22) and washer (23) from
bracket (24).
NOTE
Identify each wire and terminal during re-
moval for proper placement during instal-
lation.
f. Identify and depin wires (19) and (20) from
TB1 (25) and TB2 (26) (TM 55-1500-323-24).
g. Remove bonding jumper (27) from pylon rack
(28).
(1) Remove nut (29), washer (30), jumper (27),
and electrical lead (31).
h. Remove hollow pin (32) from rack (28) and
frame (33).
(1) Remove sealant from cover plate (34).
(2) Remove two screws (35), washers (36), and
plate (34).
(3) Remove lockwire from two pins (37).
(4) Remove two pins (37) from rack (28).
(5) Remove pin (32).
i. Remove rack (28) from frame (33).
GO TO NEXT PAGE
M04-1229-6A
22
23
21
20
19
24
21
28
2730
29
19
20
25
26
31
M04-1229-7A
32
34
36
35
36
35
28
37
33