TM 1-1520-238-23
Change 8
16-15
16.3.
PYLON RACK EJECTOR IMPULSE CARTRIDGE REMOVAL/INSTALLATION - continued
WARNING
Static electricity can accidentally fire
ejection cartridge. To prevent possible
injury to personnel or cause damage
to equipment, do not touch cartridge
primer. If injury occurs, seek medical
aid.
CAUTION
To prevent external stores jettison sys-
tem malfunction, do not install or use
damaged cartridges.
NOTE
Use CCU-44/B cartridge only.
j. Remove cartridge (4) from container (6). Do
not touch primer (5).
k. Install cartridge (4) in housing (3). Do not
touch primer (5).
(1) Mark installation date on cartridge (4). Use
marker (item 123, App F)
l. Install housing (3) with cartridge (4) in rack
(2). Torque housing (3) to 225 INCH-POUNDS.
Use torque wrench.
m. Lockwire housing (3) to ejector bolt (12). Use
wire (item 224, App F).
NOTE
Monitor service life by expiration date or
36 months after installation, whichever
occurs first.
n. Record installation date in appropriate log-
books.
o. Inspect (QA).
END OF TASK
M04-1636-5
4
6
5
M04-1636-4
3
4
2
12