PYLON RACK REMOVAL/INSTALLATION - continued
16.4.3. Removal
a. Detach connector P511 (1) from dummy re-
ceptacle J511 (2) on pylon stow bracket (3).
(1) Pull lanyard (4) to release connector (1).
b. Detach connector P512 (5) from dummy re-
ceptacle J512 (6) on bracket (3).
(1) Pull lanyard (7) to release connector (5).
c. Detach connector P513 (8) from dummy re-
ceptacle J513 (9) on bracket (3).
(1) Pull lanyard (10) to release connector (8).
NOTE
Identify each wire and terminal during re-
moval for proper placement during instal-
lation.
d. Remove wire harness (11) from bracket (3).
(1) Remove tie strap (12) from receptacle J256
(13).
(2) Depin and identify wires (14) and (15) from
receptacle J256 (13) (TM 55-1500-323-24).
(3) Remove two screws (16), washers (17), and
clamps (18) from bracket (3).
GO TO NEXT PAGE
3
8
2
5
1
9
7
6
M04-1229-5A
4
10
13
14
11
3
17
16
18
15
M04-1229-1 1
12