TM 1-1520-238-23
Change 8
16-39
16.6.
PYLON RACK EJECTOR REMOVAL/INSTALLATION
16.6.1. Description
This task covers:
Removal. Cleaning. Inspection. Installation.
16.6.2. Initial Setup
Tools:
Electrical tool kit (item 378, App H)
Light duty laboratory apron (item 27, App H)
Chemical protective gloves (item 154, App H)
5X & 12X monocular magnifier (item 206, App H)
Adjustable air filtering respirator (item 262, App H)
Materials/Parts:
Adhesive (item 16, App F)
Strap (item 193, App F)
Wire (item 230, App F)
Personnel Required:
68X
Armament/Electrical System Repairer
68X3F
Armament/Electrical System Repairer/
Technical Inspector
References:
TM 1-1520-238-T
TM 1-1520-264-23
TM 55-1500-323-24
Equipment Conditions:
Ref
Condition
16.4
Pylon rack removed
16.6.3. Removal
a. Remove ejector (1) from rack (2).
(1) Remove lockwire from piston retainer (3) and
bolt (4) on rack (2).
(2) Hold three bolts (5). Remove three nuts (6)
and washers (7).
(3) Remove three bolts (5) and three washers (7)
from rack (2) and ejector (1).
(4) Remove three bushings (8) from rack (2).
GO TO NEXT PAGE
M04-2665-2A
7
5
5
7
5
7
2
4
3
1
M04-2665-3A
8
5
6
6
2
7
7
8
1
8
7
5
5