TM 1-1520-238-23
16-44
Change 8
16.7.
PYLON RACK EJECTOR DISASSEMBLY/ASSEMBLY - continued
f. Remove retainer (12) and piston (11) from
ejector (2).
(1) Remove lockwire from retainer (12).
(2) Remove retainer (12). Use torque wrench,
torque wrench adapter, and socket.
(3) Remove and discard packing (13).
g. Remove ejector piston (11) from retainer (12).
(1) Remove and discard packing (14).
(2) Remove and discard piston ring (15).
(3) Remove and discard packing (16).
16.7.4. Cleaning
NOTE
When pylon stores are jettisoned, clean
and inspect jettison rack.
a. Clean ejector piston, orifice, and plunger. Use
dry cleaning solvent (item 74, App F) and cloth
(item 52, App F) (TM 55-1500-344-23).