TM 1-1520-238-23
16-84
Change 8
16.18.
PYLON WIRE HARNESS REPLACEMENT - continued
WARNING
Maintain pressure on preloaded
spring while removing retaining ring.
A spring-loaded mechanism can
cause injury to personnel if released
in an uncontrolled manner. Always
take care while working with the
mechanism.
j. Maintain pressure on springs (39) while per-
forming step k.
k. Identify and remove two connectors P505 (40)
and P508 (41) from connector plate (42).
(1) Remove two retaining rings (43), backing
washers (44), and springs (39) from plate
(42). Use retaining ring pliers.
(2) Remove plate (42) from top plate (45).
(3) Remove two screws (46) and washers (47).
(4) Remove retaining ring (48) from connectors
(40) and (41). Use retaining ring pliers.
(5) Remove connectors (40) and (41) from plate
(42).
l. Remove screw (49), washer (50), and clamp
(51) from bracket (52).
(1) Remove clamp (51) from harness (19).
GO TO NEXT PAGE
45
41
40
47
44
46
39
43
42
48
M04-1219-7A
49
52
51
50
19
22
45
51
19
49
50
52