TM 1-1520-238-23
16-82
Change 8
16.18.
PYLON WIRE HARNESS REPLACEMENT - continued
NOTE
This task is typical for all four pylons.
16.18.3. Removal
a. Detach connector P511 (1) from dummy re-
ceptacle J511 (2) on pylon stow bracket (3).
(1) Pull lanyard (4) to release connector (1).
b. Detach connector P512 (5) from dummy re-
ceptacle J512 (6) on bracket (3).
(1) Pull lanyard (7) to release connector (5).
c. Detach connector P513 (8) from dummy re-
ceptacle J513 (9) on bracket (3).
(1) Pull lanyard (10) to release connector (8).
d. Remove wire harness (11) from bracket (3).
(1) Remove tie strap from receptacle J256 (12).
(2) Identify and depin wires (13) and (14) from
receptacle J256 (12) (TM 55-1500-323-24).
(3) Remove two screws (15), washers (16), and
clamps (17) from bracket (3).
e. Remove clamp (18) from wire harness (19).
(1) Remove screw (20), washer (21), and clamp
(18) from bracket (22).
(2) Remove clamp (18) from harness (19).
f. Remove clamp (23) from harness (19).
(1) Remove screw (24), washer (25), and clamp
(23) from bracket (26).
(2) Remove clamp (23) from harness (19).
GO TO NEXT PAGE
4
10
5
1
3
7
8
6
2
9
M04-1219-2
3
12
13
11
15
17
14
M04-1219-3
16
24
25
19
M04-1219-4
23
26
2021
22
18
19