TM 1-1520-238-T-7
Change 3
11301
1169. PILOT DIR 1 DCPLR NO-GO PLT COMPARTMENT OR PILOT DIR 2 DCPLR
1169
NO-GO PLT COMPARTMENT APPEARS ON HOD
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provisions
R295 door open
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. With BUCS TST switch held in PLT or CPG
position, check for 28 VDC at P688125 and
P688126.
Is shear pin sheared?
YES
Go to step 2.
NO
Go to step 4.
2. Check pilot directional SPAD shear pin condition
(TM 1-1520-238-23).
Does short exist?
YES
Replace SPAD shear pin
(TM 1-1520-238-23).
NO
Go to step 3.
3. Detach P472 and P459. Check for short
between:
J2691 and J2692,
J2691 and J2694.
Does short exist?
YES
Repair shorted wire between:
J2691 and P472A19,
J2692 and P912B2,
J2694 and P912B3,
J912B2 and J459A8,
J912B3 and J459A12.
Go to paragraph 1123.
NO
Replace directional SPAD
(TM 1-1520-238-23).
4. Check for open between:
J2692 and P688125,
J2694 and P688126.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
Go to step 5.
5. Check for open between:
P12 and P13,
P13 and P14.
Does open exist?
YES
Replace directional SPAD
(TM 1-1520-238-23).
NO
(ACA) Replace DASEC
(TM 1-1520-238-23).
(ACB) Go to step 6.
6. (ACB) Detach filter adapter A708. Check for
open through pins A708125 and A708126.
Does open exist?
YES
Replace filter adapter
(TM 1-1520-238-23).
NO
Replace DASEC
(TM 1-1520-238-23).