TM 1-1520-238-T-7
11300
Change 3
1168. PILOT LAT 1 DCPLR NO-GO PLT COMPARTMENT OR PILOT LAT 2 DCPLR NO
1168
GO PLT COMPARTMENT APPEARS ON HOD
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provisions
R295 door open
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. With BUCS TST switch held in PLT or CPG
position, check for 28 VDC at P688123 and
P688124.
Is voltage present?
YES
Go to step 2.
NO
Go to step 4.
2. Check pilot cyclic lateral SPAD shear pin
condition (TM 1-1520-238-23).
Is shear pin sheared?
YES
Replace shear pin
(TM 1-1520-238-23).
NO
Go to step 3.
3. Detach P413 and P459. Check for short
between:
J2701 and J2702,
J2701 and J2704.
Does short exist?
YES
Repair shorted wire between:
J270 and P413B6,
J2702 and J459A14,
J2704 and J459A10.
Go to paragraph 1123.
NO
Replace pilot cyclic housing
(TM 1-1520-238-23).
4. Check for open between:
J2702 and P688123,
J2704 and P688124.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
Go to step 5.
5. Check for open between:
P12 and P13,
P13 and P14.
Does open exist?
YES
Replace pilot cyclic housing
(TM 1-1520-238-23).
NO
(ACA) Replace DASEC
(TM 1-1520-238-23).
(ACB) Go to step 6.
6. (ACB) Detach filter adapter A708. Check for
open through pins A708123 and A708124.
Does open exist?
YES
Replace filter adapter
(TM 1-1520-238-23).
NO
Replace DASEC
(TM 1-1520-238-23).
END OF TASK