TM 1-1520-238-23
Change 1
10-151
10.29.
FORWARD FUEL CELL INSTALLATION continued
WARNING
High pressure air exists. Air pressure
from the pneumatic vacuum cleaner
shall be vented and the regulator gage
indicate 0 psi before disconnecting
regulator. Failure to do so could cause
death or serious injury. Observe all
safety precautions.
(10) Turn knob (47) counterclockwise until 0 PSI is
indicated on gage (48).
(11) Remove filler (45) from plug (38).
r. Install fuel cell (2) on pad (49). Torque four bolts
(50) to 60 INCH-POUNDS.
(1) Install four bolts (50) and washers (51).
Torque bolts (50) to 60 INCH-POUNDS. Use
torque wrench.
(2) Perform electrical bond check on four bolts
(50) (TM 55-1500-323-24).
(a) Bond shall be 1.0 OHM or less. Use
multimeter.
(3) Seal heads of four bolts (50). Use sealing
compound (item 175, App F).
s. Remove plug (31) from fitting (32).
GO TO NEXT PAGE
M04-1913-42
38
47
48
45
M04-1913-15
M04-1913-16
31
32
49
50
51
2
M04-1913-17