TM 1-1520-238-23
11-637
11.144. CPG DIRECTIONAL SHEAR PIN ACTIVATED DECOUPLER (SPAD) REMOVAL
11.144.1. Description
This task covers:
Removal. Cleaning. Inspection.
11.144.2. Initial Setup
Tools:
Aircraft mechanics tool kit (item 376, App H)
Personnel Required:
67R
Attack Helicopter Repairer
Equipment Conditions:
Ref
Condition
1.57
Helicopter safed
2.2
Access doors B60, B65L, and B65R re-
moved; fairings L60 and R60 removed
11.144.3. Removal
a. Enter pilot station (para 1.56). Observe all
safety precautions.
b. On pilot center circuit breaker panel, open
ASE AC, DC, and BUCS circuit breakers.
c. Remove position transducer (1) from SPAD
(2).
(1) Remove and discard cotter pin (3).
(2) Remove nut (4).
(3) Remove bolt (5), washer (6), and bushing (7).
GO TO NEXT PAGE
M04-1804-1
M04-1804-2
6
7
3
4
2
1
5