TM 1-1520-238-23
16-76
Change 8
16.16.
PYLON MULTIPLEX REMOTE TERMINAL UNIT (MRTU) BRACKET
REMOVAL/INSTALLATION - continued
16.16.4. Cleaning
a. Wipe bracket with a clean rag.
16.16.5. Inspection
a. Check bracket and receptacles for cracks.
None allowed.
b. Check nutplates and receptacles for damage
(para 16.1).
c. Check bracket for corrosion (para 1.49).
d. Check bracket corners and welds for separa-
tion. Use magnifier (para 16.1)
16.16.6. Installation
a. Install bracket (1) on frame (2).
(1) Position bracket (1) on frame (2) and aline
screw holes.
(2) Install four screws (7) and washers (8).
b. Install two clamps (6) on bracket (1).
(1) Position clamps (6) on bracket (1) and aline
screw hole.
(2) Install two screws (5), washers (4), and nuts
(3).
c. Inspect (QA).
d. Install actuator and top plate assembly (para
16.9).
e. Install MRTU (TM 9-1230-476-20-1).
f. Install pylon fairings P2 and P3 (para 2.2).
END OF TASK