TM 1-1520-238-23
Change 8
16-75
16.16.
PYLON MULTIPLEX REMOTE TERMINAL UNIT (MRTU) BRACKET
REMOVAL/INSTALLATION
16.16.1. Description
This task covers:
Removal. Cleaning. Inspection. Installation.
16.16.2. Initial Setup
Tools:
Electrical tool kit (item 378, App H)
5X & 12X monocular magnifier (item 206, App H)
Personnel Required:
68X
Armament/Electrical System Repairer
68X3F
Armament/Electrical System Repairer/
Technical Inspector
References:
TM 9-1230-476-20-1
Equipment Conditions:
Ref
Condition
2.2
Pylon fairings P2 and P3
removed
16.9
Pylon actuator and top
plate removed
TM 9-1230-476-20-1
Multiplex remote terminal
unit (MRTU) removed
16.16.3. Removal
a. Remove MRTU bracket (1) from pylon frame
(2).
(1) Remove two nuts (3), washers (4), and
screws (5) from two wire harness clamps (6).
(2) Remove four screws (7) and washers (8)
from pylon frame (2).
GO TO NEXT PAGE
1
3
4
4
5
5
6
6
7
8
M04-2761-2A
7
1
8
7
2
M04-2761-3