TM 1-1520-238-23
16-78
Change 8
16.17.
PYLON STOW BRACKET REMOVAL/INSTALLATION - continued
16.17.4. Cleaning
a. Wipe stow bracket and mounting area with a
clean rag.
16.17.5. Inspection
a. Check bracket for cracks. None allowed.
b. Check bracket and mounting area for warps.
None allowed.
c. Check bracket for corrosion (para 1.49).
d. Check stow bracket receptacles for damage
(para 16.1).
16.17.6. Repair
a. Repair bracket cracks (TM 1-1500-204-23).
NOTE
The removal and installation of these four
receptacles is typical.
b. Repair bracket (1) by replacing dummy recep-
tacle J511 (12), J512 (13), J513 (14), or J526
(15).
(1) Remove cover (16) from receptacle (15).
(2) Remove four screws (17), eight washers (18),
and four nuts (19).
(3) Remove cover chain (20) and cover (16).
(4) Remove and discard receptacle (12), (13),
(14), or (15) from bracket (1).
(5) Wipe receptacle mounting area with a clean
rag.
(6) Position new receptacles (12), (13), (14), or
(15) on bracket (1) with keyway (21) facing
forward.
(7) Install top receptacles (12), (13), and (14).
(8) Install eight washers (18) and four nuts (19)
on four screws (17).
GO TO NEXT PAGE
12
1
16
14
M04-2850-3
15
13
12
16
18
19
19
18
18
17
13
17
18
M04-2850-4
21
21
18
19
15
20
1
14
18
17
18
19
17
18